| Measuring range | 0 ∼ 125 Pa |
| Accuracy | 0 ± 0.2 Pa (liner error) ± 1 % |
| Repeatability |
| Measuring range | ± 500 Pa |
| Accuracy | |
| Repeatability | ± 0.2 % FS |
| Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
| Gas | Ethylene C2H4 |
| Measure Range | 0 to 1000 ppm |
| Capacity | 50 kg |
| Accuracy | 1 g |
| Speed | 1 s |
| Measurement range | 0 ppm ∼ 5 ppm |
| Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
| Temperature range | ˗ 40 °C ∼ 120 °C |
| Measurement principle | Non-dispersive infrared (NDIR) |
| Gas Detected | SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.) |
| Detection Uncertainty | <1.5 % F.S |
| Temperature Measurement Range | -10℃ to 60℃ |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ± 1.5℃ |
| Gas Detected | O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3 |
| Detection principle | Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC) |
| Measurement Range | O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM |
| Gas Detected | Nitrogen N2 |
| Detection principle | Electrochemistry |
| Measurement Range | 0 to 100 % VOL |
| Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
| Flow rate | 1.5 L/min |
| Accuracy | 0.01 ppm or 3 % of reading |
| Sampling Method | Diffusion | ||||||
| Working conditions |
|
||||||
| Explosion proof grade | Exia II CT3 |
| Sampling method | Diffusion |
| Measurement principle | Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas) |
| Detector gas | Flammable gases, oxygen gas, toxic and harmful gases |
| Gas detected | Sulfur dioxide SO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Gas detected | NO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Sampling method | Diffusion |
| Sensor type | CO2: solid electrolyte sensor, O2:electrochemical sensor |
| Detection range | CO2:0.04 to 5.00 % and O2:0.0 to 30.0 % |
| Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
| Flow rate | 1 L/min |
| Accuracy | 0.01 ppm |