Product Categories

Spectrophotometer

Our broad list of spectrophotometers includes Visible spectrophotometers, UV/Vis spectrophotometers and Double beam UV/Vis spectrophotometers with broad wavelength range covering 190mm to 1100mm.

Atomic Absorption Spectrophotometer LAAS-A11

Monochromator
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm

Flame Atomic Absorption Spectrophotometer LAAS-A12

Wavelength range 190 nm ~ 900 nm
Spectral bandwidth 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
Wavelength accuracy ± 0.25 nm
Atomic Absorption Spectrophotometer LAAS-A13
Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A20
Monochromator
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)

Atomic Absorption Spectrophotometer LAAS-A21

Monochromator
Wavelength range 180 – 900 nm
Spectral Bandwidth 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)

Atomic Absorption Spectrophotometer LAAS-A22

Monochromator
Wavelength range 180 – 900 nm
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Fluorescence Spectrophotometer LFS-A10
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Fluorescence Spectrophotometer LFS-A11
Excitation Source 150 W Xenon Lamp
Excitation Wavelength 200 nm to 900 nm
Excitation Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm

Fluorescence Spectrophotometer LFS-A12

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

NIR Spectrophotometer LNIR-A10

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05
Nano Spectrophotometer LNS-A10
Cuvette
Temperature
PC
Nano Spectrophotometer LNS-A20
Wavelength range 190 to 850 nm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)

Nano Spectrophotometer LNS-A21

Cuvette
Temperature
PC

Nano Spectrophotometer LNS-B10

Wavelength 260 nm and 280 nm; Fixed
Spectral resolution ≤ 8 nm
Path length 0.5 mm
Nano Spectrophotometer LNS-B11
Cuvette
Temperature
PC
Nano Spectrophotometer LNS-C10
Cuvette No
Temperature
PC Inbuilt

Nano Spectrophotometer LNS-C11

Cuvette Yes
Temperature
PC Inbuilt

Nano Spectrophotometer LNS-C12

Cuvette Yes
Temperature Room Temperature 42 ºC
PC Inbuilt
Nano Spectrophotometer LNS-C13
Cuvette Yes
Temperature 4 ºC - 42 ºC (Heating & Cooling)
PC Inbuilt
Portable spectrophotometer LSP-A10
Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05
Sensor Blue light enhanced sensor array

Portable spectrophotometer LSP-A11

Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
Sensor Dual light path sensor array

Portable spectrophotometer LSP-A12

Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05
Sensor Photoelectric diode sensor
Portable spectrophotometer LSP-A13
Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.04
Sensor Photoelectric diode sensor
Portable spectrophotometer LSP-A20
Illumination Observation angles 2°/10°
Illumination: d/8 (Diffused lighting, 8° observation angle)
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
Sensor Dual light path sensor array

Portable Spectrophotometer LSP-A30

Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode

Portable Spectrophotometer LSP-A31

Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Portable Spectrophotometer LSP-A40
Optical Geometry D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)
Integrating Sphere Size Φ 40 mm
Light Source LED (Full band balanced LED)
Portable Spectrophotometer LSP-A41
Optical Geometry D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)
Integrating Sphere Size Φ 40 mm
Light Source LED (Full band balanced LED)

Portable Spectrophotometer LSP-C10

Reflect 8º(diffused illumination, 8 degree viewing angle)
Optical Geometry SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
Standards ISO7724-1, ASTM E1164, DIN5033 Teil7

Portable Spectrophotometer LSP-C11

Reflect 8º(diffused illumination, 8 degree viewing angle)
Optical Geometry SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
Standards ISO7724-1, ASTM E1164, DIN5033 Teil7
Table top spectrophotometer LTS-A10
Illumination system d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Table top spectrophotometer LTS-A11
Illumination system d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED

Table top spectrophotometer LTS-A12

Illumination system d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 15.2 cm, alvan diffused reflection surface coating
Illumination light source CLED

Table top spectrophotometer LTS-A13

Illumination system d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Table Top Spectrophotometer LTS-A15
Wavelength Range 400 nm to 700 nm
Wavelength Interval 10 nm
Sensor High sensitivity silicon photodiode
Table Top Spectrophotometer LTS-A16
Wavelength Range 360 nm to 780 nm
Wavelength Pitch 10 nm
Sensor Silicon Photodiode Array

Single Beam UV/Visible Spectrophotometer LUS-A10

Wavelength Range 190 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 1 nm

Single Beam UV/Visible Spectrophotometer LUS-A11

Wavelength Range 190 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 1.8 nm
Single Beam UV/Visible Spectrophotometer LUS-A20
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 2 nm
Single Beam UV/Visible Spectrophotometer LUS-A21
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 1.8 nm

Single Beam UV/Visible Spectrophotometer LUS-A22

Wavelength Range 190 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 0.5 nm, 1 nm, 2 nm, 4 nm adjustable

Single Beam UV/Visible Spectrophotometer LUS-A30

Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 4 nm
Single Beam UV/Visible Spectrophotometer LUS-A40
Wavelength Range 190 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
Single Beam UV/Vis Spectrophotometer LUS-A50
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Single Beam UV/Vis Spectrophotometer LUS-A51

Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Single Beam UV/Vis Spectrophotometer LUS-A52

Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV-Vis Spectrophotometer LUS-B10
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.8 nm
Optical System Double beam
Double Beam UV-Vis Spectrophotometer LUS-B11
Wavelength range 190 to 1100 nm
Spectral bandwidth 1.8 nm
Optical system Double beam; 1200 lines/mm grating

Double Beam UV-Vis Spectrophotometer LUS-B12

Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.8 nm
Optical System Double beam, C-T monochromator,1200 L/mm holographic grating

Double Beam UV-Vis Spectrophotometer LUS-B13

Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.0 nm
Optical System Double beam
Double beam UV-Visible Spectrophotometer LUS-B15
Wavelength range 190 ~ 1100 nm
Spectral bandwidth 2 nm
Wavelength accuracy 0.5 nm
Double Beam UV/Vis Spectrophotometer LUS-B16
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 nm adjustable

Double Beam UV-Vis Spectrophotometer LUS-B20

Wavelength range 190 to 1100 nm
Spectral bandwidth 1.0 to 5.0 nm (adjustable)
Optical system Double beam, C-T monochromator, 1600 L/mm holographic grating

Double Beam UV/Vis Spectrophotometer LUS-B30

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV/Vis Spectrophotometer LUS-B31
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV/Vis Spectrophotometer LUS-B32
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV-Vis Spectrophotometer LUS-B40

Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4 nm
Wavelength Accuracy ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range

Single Beam UV-Vis Spectrophotometer LUS-C10

Wavelength Range 200 to 1000 nm
Spectral Bandwidth 4.0 nm
Optical System Single beam
Vis Spectrophotometer LVS-A10
Wavelength Range 330 to 1000 nm
Setting Wavelength
Spectral Bandwidth 5 nm
Vis Spectrophotometer LVS-A11
Wavelength Range 335 ~ 1000 nm
Setting Wavelength
Spectral Bandwidth 4 nm

Visible Spectrophotometer LVS-A20

Photometry Single Beam
Monochromatic Type Czerny-Turner
Wavelength range 340 to 1000nm

Visible Spectrophotometer LVS-A21

Photometry Single Beam
Monochromatic Type Czerny-Turner
Wavelength range 325 to 1000nm
Visible Spectrophotometer LVS-A30
Wavelength range 320 to 1100 nm
Spectral bandwidth 2.0 nm
Wavelength Accuracy ± 0.8 nm
Vis Spectrophotometer LVS-B10
Wavelength Range 325 ~ 1000 nm
Setting Wavelength Automatic
Spectral Bandwidth 2 nm

Vis Spectrophotometer LVS-C10

Wavelength Range 320 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 4 nm

Vis Spectrophotometer LVS-C11

Wavelength Range 320 ~ 1000 nm
Setting Wavelength
Spectral Bandwidth 2 nm
Xenon Lamp Spectrophotometer LXLS-A10
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Xenon Lamp Spectrophotometer LXLS-A11
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm

Xenon Lamp Spectrophotometer LXLS-A13

Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm

Xenon Lamp Spectrophotometer LXLS-A14

Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm