Our broad list of spectrophotometers includes Visible spectrophotometers, UV/Vis spectrophotometers and Double beam UV/Vis spectrophotometers with broad wavelength range covering 190mm to 1100mm.
Monochromator | |
Wavelength range | 190 - 900 nm |
Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
Wavelength range | 190 nm ~ 900 nm |
Spectral bandwidth | 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm |
Wavelength accuracy | ± 0.25 nm |
Working spectral range | 190 to 900 nm |
Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
Wavelength accuracy | ± 0.15 nm |
Monochromator | |
Wavelength range | 180 - 900 nm |
Spectral Bandwidth | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) |
Monochromator | |
Wavelength range | 180 – 900 nm |
Spectral Bandwidth | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) |
Monochromator | |
Wavelength range | 180 – 900 nm |
Spectral Bandwidth | 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting |
Light source | 150 W Xenon lamp |
Excitation wavelength | 200 nm to 900 nm |
Emission wavelength | 200 nm to 900 nm |
Excitation Source | 150 W Xenon Lamp |
Excitation Wavelength | 200 nm to 900 nm |
Excitation Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
Light source | 150 W Xenon lamp |
Excitation wavelength | 200 nm to 900 nm |
Emission wavelength | 200 nm to 900 nm |
Wavelength Range | 900 nm to 2500 nm |
Wavelength Accuracy | ≤ 0.2 |
Wavelength Reproducibility | ≤ 0.05 |
Cuvette | |
Temperature | |
PC |
Wavelength range | 190 to 850 nm |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
Cuvette | |
Temperature | |
PC |
Wavelength | 260 nm and 280 nm; Fixed |
Spectral resolution | ≤ 8 nm |
Path length | 0.5 mm |
Cuvette | |
Temperature | |
PC |
Cuvette | No |
Temperature | |
PC | Inbuilt |
Cuvette | Yes |
Temperature | |
PC | Inbuilt |
Cuvette | Yes |
Temperature | Room Temperature 42 ºC |
PC | Inbuilt |
Cuvette | Yes |
Temperature | 4 ºC - 42 ºC (Heating & Cooling) |
PC | Inbuilt |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | Blue light enhanced sensor array |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03 |
Sensor | Dual light path sensor array |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | Photoelectric diode sensor |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.04 |
Sensor | Photoelectric diode sensor |
Illumination | Observation angles 2°/10° Illumination: d/8 (Diffused lighting, 8° observation angle) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04 |
Sensor | Dual light path sensor array |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Optical Geometry | D/8 (diffused illumination,8° viewing), Specular Component Included (SCI) |
Integrating Sphere Size | Φ 40 mm |
Light Source | LED (Full band balanced LED) |
Optical Geometry | D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded) |
Integrating Sphere Size | Φ 40 mm |
Light Source | LED (Full band balanced LED) |
Reflect | 8º(diffused illumination, 8 degree viewing angle) |
Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
Reflect | 8º(diffused illumination, 8 degree viewing angle) |
Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
Illumination system | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Illumination system | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Illumination system | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 15.2 cm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Illumination system | d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Wavelength Range | 400 nm to 700 nm |
Wavelength Interval | 10 nm |
Sensor | High sensitivity silicon photodiode |
Wavelength Range | 360 nm to 780 nm |
Wavelength Pitch | 10 nm |
Sensor | Silicon Photodiode Array |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | |
Spectral Bandwidth | 1 nm |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | |
Spectral Bandwidth | 1.8 nm |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 2 nm |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 1.8 nm |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | |
Spectral Bandwidth | 0.5 nm, 1 nm, 2 nm, 4 nm adjustable |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 4 nm |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | |
Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 0.5/1/2/4/5 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Range | 190 to 1100 nm |
Spectral Bandwidth | 1.8 nm |
Optical System | Double beam |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1.8 nm |
Optical system | Double beam; 1200 lines/mm grating |
Wavelength Range | 190 to 1100 nm |
Spectral Bandwidth | 1.8 nm |
Optical System | Double beam, C-T monochromator,1200 L/mm holographic grating |
Wavelength Range | 190 to 1100 nm |
Spectral Bandwidth | 1.0 nm |
Optical System | Double beam |
Wavelength range | 190 ~ 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength accuracy | 0.5 nm |
Wavelength Range | 190 ~ 1100 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 nm adjustable |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1.0 to 5.0 nm (adjustable) |
Optical system | Double beam, C-T monochromator, 1600 L/mm holographic grating |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 0.5/1/2/4/5 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 0.5/1/2/4 nm |
Wavelength Accuracy | ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range |
Wavelength Range | 200 to 1000 nm |
Spectral Bandwidth | 4.0 nm |
Optical System | Single beam |
Wavelength Range | 330 to 1000 nm |
Setting Wavelength | |
Spectral Bandwidth | 5 nm |
Wavelength Range | 335 ~ 1000 nm |
Setting Wavelength | |
Spectral Bandwidth | 4 nm |
Photometry | Single Beam |
Monochromatic Type | Czerny-Turner |
Wavelength range | 340 to 1000nm |
Photometry | Single Beam |
Monochromatic Type | Czerny-Turner |
Wavelength range | 325 to 1000nm |
Wavelength range | 320 to 1100 nm |
Spectral bandwidth | 2.0 nm |
Wavelength Accuracy | ± 0.8 nm |
Wavelength Range | 325 ~ 1000 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 2 nm |
Wavelength Range | 320 ~ 1100 nm |
Setting Wavelength | |
Spectral Bandwidth | 4 nm |
Wavelength Range | 320 ~ 1000 nm |
Setting Wavelength | |
Spectral Bandwidth | 2 nm |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 1 nm |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 1 nm |
Copyright @ labtrononline.com