Deionized Water System LDIN-A10

Deionized Water System LDIN-A10 is smallest and most compact lab water system from tap to ultrapure water, integrating pretreatment, RO, DI, UV, UF and terminal filter into one. Its output ranges from 15 to 30 liters/hour and offers flow rate up to 2 liters/minute (with pressure tank). Features with tap water inlet, it can produce single stage RO water and deionized water. The single stage RO water’s ion rejection rate is more than 96%, and the deionized water’s resistivity is more than 15 MΩ.cm, near to 18.2 MΩ.cm. It completely meets the requirements of general chemical or biological experiments for pure water. Designed with apheliotropic LCD display, to detect the quality of deionized or ultrapure water. Equipped with Ultrafiltration module, effectively eliminate endotoxin and suitable for precise cell cultivating and IVF. Double wavelength (185 & 254 nm) ultraviolet lamp module, restrain bacteria increase and reduce TOC. It is auto self-flushing of RO membrane function, extend RO membrane life.

Get Catalog
Output 30 liters/hour
Flow rate Up to 2 liters/minute (with pressure tank)
Pure water outlet 2 reverse osmosis water, deionized water
Deionized Water Quality Resistivity: 16 to 18.2 M Ω cm
Bacteria: N/A
Particle (>0.1 µm): N/A
RO Water Quality Ion rejection rate: 97 % to 99% (new RO membrane)
Organic rejection rate: >99 %, when MW >200 Dalton
Particles and bacteria rejection rate: >99 %
Feed water requirements Tap water, Temperature 5 to 45°C, Pressure 1.0 to 4.0 Kgf/cm2
Dimension 410 × 220 × 420 mm 
Power Consumption 72 W
Power Supply AC100 to 240 V, 50/60 Hz
Weight about 18 kg
Standard configuration Main body (Including 1 set of cartridge) +15 liters pressure tank+ TDS/conductivity test pen
  • Designed with microcomputer controlling system and electronic pressure sensor
  • Auto self-flushing of RO membrane function, extend RO membrane life
  • Equipped with top cap of pretreatment in the case can be rapidly opened to replace the cartridges without opening the case
  • Offers 4 independent ultrapure cartridges
  • Ultrapure water quality up to 18.2 MΩ.cm, with the lowest TOC level and running cost
  • Whole unit with one time injection molding process
  • Material used polypropylene, avoid rusting and keep clean, to meet GLP standard
  • Designed with apheliotropic LCD display, to detect the quality of deionized or ultrapure water
  • Offers attached portable TDS (total dissolved solid) conductivity test pen, with dry cell design, to detect the quality of feed water and RO water
  • Double wavelength (185 & 254 nm) ultraviolet lamp module, restrain bacteria´s increase and reduce TOC
  • Ultrafiltration module, effectively eliminate endotoxin and suitable for precise cell cultivating and IVF
  • Double layer PES terminal disinfection filter, assure that terminal pure water is absolutely axenic

Deionized Water System is used in general chemical or biological experiments to obtain deionized and RO water across Healthcare, Food & Beverage and Biochemistry microanalysis etc.

Request Quote

Type I and Type III Water Purification System

This water purification system is a combinational system that produces Type III water after RO and Type I water after deionization in one cycle

Type I and Type III Water Purification System : Type I and Type III RO Water Purification System LOTW-B10
Output of Pure water≥ 10 L / hr.
Water TypeType I and Type III
Water Tank capacity30 L
Type I and Type III Water Purification System : Type I and Type III RO Water Purification System LOTW-B11
Output of Pure water≥ 20 L / hr.
Water TypeType I and Type III
Water Tank capacity30 L
Type I and Type III Water Purification System : Type I and Type III RO Water Purification System LOTW-B12
Output of Pure water≥ 30 L / hr.
Water TypeType I and Type III
Water Tank capacity30 L

Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Type II Water Purification System : Type II Water Purification System LTWP-B10
Output of Pure water≥ 10 L / hr.
ProcessDouble Pass RO system
Water TypeType II
Type II Water Purification System : Type II Water Purification System LTWP-B11
Output of Pure water≥ 20 L / hr.
ProcessDouble Pass RO system
Water TypeType II
Type II Water Purification System : Type II Water Purification System LTWP-B12
Output of Pure water≥ 30 L / hr.
ProcessDouble Pass RO system
Water TypeType II

Type III Water Purification System

It provides Type III level water which is required for chemical and physical inspection or for washing lab glassware’s

Type III Water Purification System : Type III Water Purification System LHWP-B10
Output of Pure water≥ 10 L / hr.
Water TypeType III
ConfigurationBenchtop
Type III Water Purification System : Type III Water Purification System LHWP-B11
Output of Pure water≥ 20 L / hr.
Water TypeType III
ConfigurationBenchtop
Type III Water Purification System : Type III Water Purification System LHWP-B12
Output of Pure water≥ 30 L / hr.
Water TypeType III
ConfigurationBenchtop

Radio Frequency Identification Water Purification System

Radio Frequency Identification Water Purifier are equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. This helps in monitoring of parameters for the purifier

Radio Frequency Identification Water Purification System : Radio Frequency Identification Water Purification System LRFW-B10
Output of Pure water≥ 10 L / hr.
ProcessDouble Pass RO system
ConfigurationBenchtop
Radio Frequency Identification Water Purification System : Radio Frequency Identification Water Purification System LRFW-B11
Output of Pure water≥ 20 L / hr.
ProcessDouble Pass RO system
ConfigurationBenchtop
Radio Frequency Identification Water Purification System : Radio Frequency Identification Water Purification System LRFW-B12
Output of Pure water≥ 30 L / hr.
ProcessDouble Pass RO system
ConfigurationBenchtop

UV Water Purification System

UV water purification systems destroy the DNA of micro-organisms making the water contamination free. Water produced from UV water purification is contamination free water which is potable for consumption

UV Water Purification System : UV Water Purification System LUVW-B10
Output of Pure water≥ 10 L / hr.
ProcessDouble Pass RO system
ConfigurationBenchtop
UV Water Purification System : UV Water Purification System LUVW-B11
Output of Pure water≥ 20 L / hr.
ProcessDouble Pass RO system
ConfigurationBenchtop
UV Water Purification System : UV Water Purification System LUVW-B12
Output of Pure water≥ 30 L / hr.
ProcessDouble Pass RO system
ConfigurationBenchtop

Water Purification System (Feed-specific)

Water Purification System (Feed-specific) : Water Purification System LWPS-A10
Water qualityOne stage (Type I)
Feed waterRO water /Distilled water Water temperature: 5 ~ 40℃
Conectivity
Water Purification System (Feed-specific) : Water Purification System LWPS-A11
Water qualityTwo stage(Type III and type I)
Feed waterTap waterTDS≤400ppm Water temperature: 5-40℃ Type 3 water ≥10L/h
Conectivity
Water Purification System (Feed-specific) : Water Purification System LWPS-C10
Output 2nd stage RO water90 liters/hour
Output ultrapure waterUp to 2 liters/minute (when tank is full)
Ultrapure Water QualityResistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm):

Deionized Water System

Deionized Water System : Deionized Water System LDIN-A20
Output30 liters/hour
Flow rateUp to 2 liters/minute (with pressure tank)
Pure water outlet2 reverse osmosis water, deionized water