Get Catalog| Temperature control range | RT. (-30) °C - 100°C |
| Temperature setting range | (-10) ℃ - 100 ℃ |
| Temperature accuracy | ≤ ± 0.3 °C |
| Temperature uniformity | ≤ ± 0.3 °C |
| Heating time | ≤ 10 min (25°C ~ 100°C) |
| Cooling time | ≤ 10 min (100°C ~ 25°C) / ≤ 25 min (from room temp. to under it 30°C) |
| Display accuracy | 0.1°C |
| Time range | 1 min - 99 hr. 59 min |
| Auto warming | Yes |
| Auto running | Yes |
| Auto heating | Yes |
| Auto resume to run | Yes |
| Multi points running | Yes (Max. 5 points) |
| Multi points running circularly | Yes (Max. 99 times) |
| Voltage | AC 110 V - 220 V / 50 - 60 Hz |
| Power | 150 W |
| Fuse | 250 V / 3A / ɸ5 x 20 |
| Dimension (L x W x H) | 260 x 195 x 150 mm |
| Net weight | 4.5 kg |
| Gross Weight | 4.5 kg |
Dry bath incubator can be used in sample preparation, sample coagulation, enzyme-substrate reaction and DNA amplification. It is also used for ligation reaction and storing oocytes.
Request Quote
It incorporates advantage of both closed and shaking incubation required for no. of processes which includes tissue culture, enzyme reaction, fermentation etc. It is highly efficient with user-friendly operation.
This wide range of cooling incubators is available in different temperature ranges and it is suitable to serve for preservation of culture medium, serum, medicine as well as micro-organism training and environmental testing, etc.
Equipped with inner glass door for easy operation, our heating incubators deliver a higher level of performance for storage and cultivation purpose. This range is available in different chamber volume.

| Control System | Microcomputer control system |
| Display | LCD display with button-press keypad |
| Time for creating anaerobic state in sample chamber | < 5 minutes |

| Control System | Microprocessor control system + Siemens PLC |
| Display | LCD display with touch screen control panel |
| Time for creating anaerobic state in sample chamber | < 5 minutes |

| Air cycle Mode | Gravity air convection |
| Function | RT +5 to 50 ℃, 0.1 ℃, ± 0.5 ℃, ± 1.5 ℃ |
| Body structure | Mirror stainless steel, Cold rolling steel electrostatic spraying exterior, 6.5 cm polyurethane interlayer, Nickel and chromium alloy heating wire |

| Air cycle Mode | Natural air convection |
| Function | RT +5 to 80 ℃, 1 ℃, ± 1.0 ℃, ± 1.5 ℃ |
| Body structure | Stainless steel, Galvanized steel, Polyurethane interlayer, Explosion proof alloy heating wire |