ICP Spectrometer LICP-A11 detects micro and macro elements using argon plasma with an analyzing rate of 15 elements per minute. Results can be achieved with lower levels of detection for qualitative and quantitative analysis. Detection of liquid flow from the spray chamber by optical drain sensor offers exceptional sensitivity and accuracy. Accurate signal-background ratio is attained by advanced control system.
Get Catalog| Wavelength range | 180 to 900 nm |
| Elements per minute | 15 elements |
| Temperature | 29 °C |
| Incident slit | 25 µm |
| Standard deviation | RSD ≤ 2 % |
| Correlation coefficient | ≥ 0.9995 % |
| Gas source | Argon ( 99.99 % ) |
| Plasma gas flow meter | 100 – 1000 L / h ( 1.6 - 16 L / min ) |
| Auxillary gas flow meter | 10 – 100 L / h ( 0.16 – 1.66 L / min ) |
| Carrier gas flow meter | 0 ~ 5 L / min |
| Cooling water flow rate | 5 L / min |
| Cooling water temperature | 20 ~ 26 °C |
| Water outlet diameter | 10 mm |
| Line dispersion rate | 0.26 nm |
| Resolving power | ≤ 0.007 nm |
| Co-axial sprayer diameter | 6 mm |
| Coil diameter | 25 mm |
| Double room fog diameter | 34 mm |
| Quartz tube torch diameter | 20 mm |
| Mirror dimensions | 80 x 110 x 16 mm |
Used in clinical analysis for detection of metals in biological fluids , environmental analysis for trace element detection in water , soil , plants , pharmaceuticals for traces of catalysts and poison metals like Cd , Pb , industries for noble metal detection
Request Quote

| Wavelength range ( 3600 lines / mm ) | 180 to 500 nm |
| Wavelength range ( 2400 lines / mm ) | 180 to 800 nm |
| Temperature | 20 ~ 28 °C |

| Monochromator Specifications | Czerny turner, ≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating), 1000 mm, huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area, 195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating |
| Solid State Power Specifications | 27.12 MHz Frequency stability: < 0.05%, Scott double pass spray chamber, 800 W to 1600 W, adjustable with power efficiency more than 65%, ≤ 0.05%, 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter) |
| Technical Specifications | Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%, short-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2%, 5 to 8 elements / min, 1ppb to 10ppb |

| Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
| Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
| Range | Simultaneous detector |