Portable Vibration Calibrator LPVC-A10

Portable Vibration Calibrator LPVC-A10 is a tabletop unit with standard sine signals at continually varying frequency from 10 Hz to 1280 Hz. LCD digital panel displays defined amplitude of the acceleration, velocity and displacement. Either horizontal or vertical vibration can be generated. It is an all in one unit combining sine signal generator, power amplifier, standard transducer and a shaker.

Get Catalog
Frequency (continually adjustable) 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ) 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ) 40 Hz to 320 Hz + 0.5dB +1 digit
Amplitude displacement ( at 50 μm pk-pk ) 40 Hz to 320 Hz + 0.5 dB + 1 digit
Probe 5 mm , 8 mm and 11mm probe
Probe range 0 ~ 2.0 mm
Display 3 ½ digit display
Storage -20 °C to 70 °C
Operational temperature 0 °C to 50 °C
Humidity 90 % non-condensing
Dimensions 280 x 180 x 250 mm
Weight 9 kgs
  • Measures acceleration, velocity and displacement
  • Continuous varying frequency
  • Horizontal or vertical vibrational modes

Used to calibrate vibration monitoring / measuring instruments or data acquisition / data collector devices

Request Quote

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Whiteness meter TP-A11
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
Sample (size) length38×70 mm
Sample width
Measuring range(1-500) mN.m (divided into 7 small ranges)

Plastic Testing Instruments

Plastic Testing Instruments : Aging Oven TAO-A10
The maximum temperature300°C
Temperature fluctuationWithin ± 0.5°C
Temperature uniformityWithin ± 1°C
Plastic Testing Instruments : Vacuum Leak Tester TVLT-A10
Vacuum degree0 to 90 KPa
Accuracy1 % FS
Resolution0.1 KPa
Plastic Testing Instruments : Oxygen Index Tester TOIT-A10
Vacuum degree
Accuracy
Resolution0.1 % O2

Rubber Testing Instruments

Rubber Testing Instruments : Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control rangeRoom temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy± 0.3 ℃
Impact speed0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Rubber Testing Instruments : Three roll mill machine TRMM-A10
Mixed capacity0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature rangeRT to 300°C
Temperature control systemPID control
Rubber Testing Instruments : DIN abrasion tester TDAT-A10
Test arm weight2.5 N
Additional Loads2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler150 mm

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test306, 613, 1839 N

Soil Testing Instruments

Soil Testing Instruments : Soil nutrient tester TSNA-A10
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil nutrient tester TSNA-A11
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil Salinity tester TSST-A10
Salinity Measurement range0.00 to 19.99 ms/cm
Measuring accuracyEC ± 2% full scale
Temperature Measurement range-5 to 50°C