Product Categories

Testing Instruments

Portable Vibration Calibrator LPVC-A10

Frequency (continually adjustable) 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ) 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ) 40 Hz to 320 Hz + 0.5dB +1 digit

Aging Oven TAO-A10

The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C

Benchtop gloss meter TBGM-A10

Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU

Charpy/ Izod Impact Tester TCI-A10

Impact Speed & Energy (charpy) 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod) 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy 0.001 J

DIN abrasion tester TDAT-A10

Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm

Digital Brinell hardness Tester TDBH-A10

Test force 612.5 N, 980 N, 1225 N
Brinell hardness test 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
Hardness measuring area 8 to 650 HBW (hard metals steel ball)

Digital low load Vickers Hardness tester TDVH-A10

Test force 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Brinell hardness test
Hardness measuring area

Falling Weight Impact Tester TFWT-A10

Vacuum degree
Accuracy
Resolution

Heat sealer THS-A10

Seal temperature Room temperature -250°C
Control accuracy ± 0.2°C
Dwell time 0.1 S to 999.9 S

Lasting adhesive tester TLAT-A10

Standard roller 2000 ± 50 g
Testing stations 3
Dimension (L*W*H) tester 320×210×550 mm (3 stations)

Lasting adhesive tester TLAT-A11

Standard roller 2000 ± 50 g
Testing stations 6
Dimension (L*W*H) tester 650×210×550 mm (6 stations)

Melt flow Indexer TMFI-A10

Measuring range 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
Measuring rate 0.001 S
Temperature range 50 to 400°C

Melt flow Indexer TMFI-A11

Measuring range 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
Measuring rate 0.001 S
Temperature range 50 to 400°C

Mooney viscometer TMV-A10

Test arm weight
Additional Loads
Idler

No rotor rheometer TNRR-A10

Test arm weight
Additional Loads
Idler

Oxygen Index Tester TOIT-A10

Vacuum degree
Accuracy
Resolution 0.1 % O2

Whiteness and chromaticity tester TP-A10

Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range

Whiteness meter TP-A11

Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range

Tensile Stiffness Tester TP-B10

Sample (size) length 38×70 mm
Sample width
Measuring range (1-500) mN.m (divided into 7 small ranges)

Automatic horizontal tensile tester TP-B11

Sample (size) length 90 to 200 mm
Sample width 15 mm, 25 mm, 50mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N

Automatic horizontal tensile tester TP-B12

Sample (size) length 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width 15 mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N

Vertical tensile tester TP-B20

Sample (size) length 0 to 200 mm adjustable
Sample width 15 mm
Measuring range 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N

Pulp beating (refining) freeness tester TP-C10

Measurement range 0 to 100° SR
Slider weight
Slider size

Water absorption tester TP-C20

Measurement range 0 to 200 mm
Slider weight
Slider size

Water absorption tester- Cobb Tester TP-C21

Measurement range
Slider weight
Slider size

COBB sample cutter TP-C30

Measurement range
Slider weight
Slider size

Coefficient of friction tester TP-D10

Measurement range 0.01 to 10 N
Slider weight 200 g
Slider size 63×63 mm

Electronic bending stiffness tester TP-E10

Sample size (L*B)
Rub pressure
Friction speed

Paper and cardboard thickness meter TP-E20

Sample size (L*B)
Rub pressure
Friction speed

Paper and cardboard thickness meter TP-E21

Sample size (L*B)
Rub pressure
Friction speed

Ink rubber tester TP-F10

Sample size (L*B) 230×50 mm (can join short samples together)
Rub pressure 20 ± 0.2 N
Friction speed 43 times / min

Standard strip cutter TP-G10

Sample size (L*B)
Rub pressure
Friction speed

Softness tester TP-H10

Sample size (L*B)
Rub pressure
Friction speed

Carton compression tester TP-I10

Measuring range 0.1 to 10 kN
Capacity
Resolution

Carton compression tester TP-I11

Measuring range 1 to 50 kN
Capacity
Resolution

Paper air permeability tester TP-J10

Measuring range 0 to 1000 ml/min
Capacity
Resolution

Internal Ply bond Tester TP-J11

Measuring range
Capacity A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Resolution

Puncture strength tester TP-J12

Measuring range A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
Capacity
Resolution

Paper tearing tester TP-J20

Measuring range 0 to 1000 mN
Capacity
Resolution 0.1 mN

Electronic Tearing tester TP-J21

Measuring range
Capacity 10 -16000 mN
Resolution 0.1 mN

Mullen burst tester TP-K10

Measurement range 0 to 5600 kPa
Measuring scope
Folding angle

Mullen burst tester TP-K11

Measurement range 0 to 1600 kPa
Measuring scope
Folding angle

Crush tester TP-L10

Measurement range 5 to 500 N, 50 to 3000 N
Measuring scope
Folding angle

Bekk Smoothness tester TP-L20

Measurement range
Measuring scope ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Folding angle

Folding endurance tester TP-M10

Measurement range
Measuring scope 0 to 99999 s
Folding angle 135° ± 2°

Primary adhesive tester TPAT-A10

Inclined adjustable angle 0 to 40°
Panel width 120 mm
Test area width 80 mm

Rubber low temperature brittleness tester TRBT-A10

Temperature range -60°C to 0°C
Temperature accuracy ± 0.5°C
Measuring range

Rubber Low Temperature Brittleness Tester TRBT-A11

Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min
-30℃ to -40℃ around 2.5 ℃/min
-40℃ to -70℃ around 2.0 ℃/min

Rockwell hardness meter TRHM-A10

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test

Rockwell hardness meter TRHM-A11

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test

Rockwell hardness meter (motorized type) TRHM-B10

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N

Three roll mill machine TRMM-A10

Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control

Rubber-weiss plasticity testing machine TRWM-A10

Temperature range RT 50° to 300°
Temperature accuracy ± 1°
Measuring range 0.01 to 25 mm

Soil water hardness meter TSHM-A10

Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %

Soil water hardness meter TSHM-A11

Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %

Soil moisture meter TSMM-A10

Measurement range 0 to 80 %
Resolution 0.1
Accuracy ± 2 % n (non-saturation condition)

Soil moisture meter TSMM-A11

Measurement range 0 to 90 %
Resolution 0.1 or 0.01
Accuracy ± 5 % n (non-saturation condition)

Soil moisture meter TSMM-A12

Measurement range 0 to 60 %
Resolution 0.1
Accuracy ± 5 % n (non-saturation condition)

Soil nutrient tester TSNA-A10

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %

Soil nutrient tester TSNA-A11

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %

Soil Salinity tester TSST-A10

Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C

Soil Water potential tester TSWT-A10

Measuring range 0 to 100 kPa
Resolution 0.01 kPa
Accuracy ± 1 kPa

Vicat softening temperature & HDT machine TVHT-A10

Operating temperature Ambient temperature to 300°C
Heating rate 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
Maximum temp. error with heating speed ± 5°C under 50°C/ h, ± 1°C under 120°C/ h

Vacuum Leak Tester TVLT-A10

Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa