Charpy/ Izod Impact Tester TCI-A10

Charpy/ Izod Impact Tester TCI-A10 comes with LCD digital display, pendulum design which concentrates energy at the impact point with minimum energy loss which occurs due to vibrations. It comes with broad range of measurement methods like test for split strength, impact intensity, fore elevation, ascending angle, statistics function, and automatic correction energy loss. With high precision & performance this charpy/ Izod Impact Tester is complied in accordance with ISO 179 for charpy, ISO 180, ASTM D256 for Izod test methods.

Get Catalog
Impact Speed & Energy (charpy) 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod) 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy 0.001 J
Pendulum up angle 160°
Impact center distance (Charpy) 221 mm for 1J, 2J, 4J, 5J & 380 mm 7.5J, 15J, 25J
Impact center distance (Izod) 322 mm
Charpy distance between the clamps 40 mm, 60 mm, 70 mm, 95 mm
Radius of striking edge (IZOD) 0.8 mm
Radius of striking edge (Charpy) 2.0 mm
Distance between jaw & impact edge: 22mm
Dimension 460×330×745 mm
Weight 190 kg
Power 110V/ 220V , 60Hz/ 50Hz
  • Innovative design impact tester used for both Izod and Charpy test
  • Adopted with LCD digital display to view measuring circle angle
  • Pendulum up angle 160°
  • Precise impact speed and center distance values for Charpy & Izod materials
  • Resolution of impact energy 0.001 J
  • Can be connected to mini printer to print results

It is used to test plastic sheets, glass-steel sheets, plastic pipe & other non-metallic materials sheets or insulators of plastic for anti-impact, anti- charpy intensity.

Request Quote

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Whiteness meter TP-A11
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
Sample (size) length38×70 mm
Sample width
Measuring range(1-500) mN.m (divided into 7 small ranges)

Plastic Testing Instruments

Plastic Testing Instruments : Aging Oven TAO-A10
The maximum temperature300°C
Temperature fluctuationWithin ± 0.5°C
Temperature uniformityWithin ± 1°C
Plastic Testing Instruments : Vacuum Leak Tester TVLT-A10
Vacuum degree0 to 90 KPa
Accuracy1 % FS
Resolution0.1 KPa
Plastic Testing Instruments : Oxygen Index Tester TOIT-A10
Vacuum degree
Accuracy
Resolution0.1 % O2

Rubber Testing Instruments

Rubber Testing Instruments : Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control rangeRoom temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy± 0.3 ℃
Impact speed0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Rubber Testing Instruments : Three roll mill machine TRMM-A10
Mixed capacity0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature rangeRT to 300°C
Temperature control systemPID control
Rubber Testing Instruments : DIN abrasion tester TDAT-A10
Test arm weight2.5 N
Additional Loads2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler150 mm

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test306, 613, 1839 N

Soil Testing Instruments

Soil Testing Instruments : Soil nutrient tester TSNA-A10
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil nutrient tester TSNA-A11
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil Salinity tester TSST-A10
Salinity Measurement range0.00 to 19.99 ms/cm
Measuring accuracyEC ± 2% full scale
Temperature Measurement range-5 to 50°C