| Number of basket lifting set | 1 set |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Number of basket lifting set | 2 sets |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Number of basket lifting set | 3 sets |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| No of vessels | 1 |
| No of poles | 1 |
| Position of vessels and poles | One vessel and one pole arranged on one line |
| No of vessels | 3 |
| No of poles | 3 |
| Position of vessels and poles | Three vessel and three pole arranged on one line |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| No of vessels | 8 |
| No of poles | 8 |
| Position of vessels and poles | Four vessels and four poles in front and others at back |
| No of vessels | 12 |
| No of poles | 12 |
| Position of vessels and poles | Six vessels and six poles in front and other six poles and vessels at back |
| Disc | Diameter 100 mm |
| Funnel Outer Diameter | Outer diameter 155 mm |
| Funnel Inner Diameter | 145 mm |
| Material Stainless | 316 L Stainless Steel |
| Automatic Grade | Semi-Automatic |
| Power Source | Pneumatic |
| Maximum pressure | 60 KN |
| Maximum diameter Tablet | 25 mm |
| Maximum depth of filling | 16 mm |
| Maximum pressure | 50 KN |
| Maximum diameter Tablet | 20 mm |
| Maximum depth of filling | 12 mm |
| Maximum pressure | 15 KN |
| Maximum diameter Tablet | 12 mm |
| Maximum depth of filling | 11 mm |
| Diameter of counting plate | 400 mm |
| Hole No. of counting slide/range | 5 to 100 (optional) |
| Production efficiency | 10 to 20 vials/ min |
| Work Station | 1 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Work Station | 2 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Work Station | 3 |
| Sample Volume | ≤ 100 ml |
| Sample Weight | ≤ 500 g |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 20 to 100 rpm can be set arbitrarily |
| Rotating accuracy | ± 1 rpm |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm can be set arbitrarily |
| Rotating accuracy | ± 1 rpm |
| Number of cylinder | 1 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Hardness measurement range | 2 to 196 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 20 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
Copyright @ labtrononline.com