Digital low load Vickers Hardness tester TDVH-A10

Digital low load Vickers Hardness tester TDVH-A10 comes with large LCD screen to display the parameters like test mode, test pressure, indention length, hardness values, pressure holding time and number of test for study. Equipped with dual channel high resolution optical measuring system, integrated computer programming technology and photoelectrical techniques gives reliable results. Tests thin samples or its parts of nonmetallic materials after the coating in research institutes, factories, labs.

Get Catalog
Test force 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol HV1, HV5, HV10, HV20, HV30, HV250
Error range in display ± 3.0 %, ± 2.0 %
Hardness indication Digital display
Hardness value range in Measure 5 HV to 2500 HV
Magnification of Microscope 100x
Loading control Automatic
Pressure holding time 5 to 60 S
Min. measurable unit 0.25 µm
Max. height of sample 160 mm
Distance from intenders center to outer wall 135 mm
Illumination light LED
Main body weight Approx. 40 kg
Dimension of machine 540 × 220 × 650 mm
Power supply AC 220 V, 50 Hz
  • Large LCD display
  • Camera & eyepiece for indention photography & metallography
  • Light source adjustments
  • Soft key input
  • Data recording and data processing
  • RS232 interface for printing output, connection to PC

Digital low load Vickers Hardness tester finds application in research institutes, factories, and quality departments for plastic and other non-metals hardness testing.

Request Quote

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Whiteness meter TP-A11
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
Sample (size) length38×70 mm
Sample width
Measuring range(1-500) mN.m (divided into 7 small ranges)

Plastic Testing Instruments

Plastic Testing Instruments : Aging Oven TAO-A10
The maximum temperature300°C
Temperature fluctuationWithin ± 0.5°C
Temperature uniformityWithin ± 1°C
Plastic Testing Instruments : Vacuum Leak Tester TVLT-A10
Vacuum degree0 to 90 KPa
Accuracy1 % FS
Resolution0.1 KPa
Plastic Testing Instruments : Oxygen Index Tester TOIT-A10
Vacuum degree
Accuracy
Resolution0.1 % O2

Rubber Testing Instruments

Rubber Testing Instruments : Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control rangeRoom temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy± 0.3 ℃
Impact speed0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Rubber Testing Instruments : Three roll mill machine TRMM-A10
Mixed capacity0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature rangeRT to 300°C
Temperature control systemPID control
Rubber Testing Instruments : DIN abrasion tester TDAT-A10
Test arm weight2.5 N
Additional Loads2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler150 mm

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test306, 613, 1839 N

Soil Testing Instruments

Soil Testing Instruments : Soil nutrient tester TSNA-A10
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil nutrient tester TSNA-A11
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil Salinity tester TSST-A10
Salinity Measurement range0.00 to 19.99 ms/cm
Measuring accuracyEC ± 2% full scale
Temperature Measurement range-5 to 50°C