Lasting adhesive tester TLAT-A10

Lasting adhesive tester TLAT-A10 comes with test plate having adhesive specimen hanged virtually on the stand & its bottom is attached with standard weight. The lasting adhesive property could be obtained by measuring the displacement of specimen on vertical test plate or the time to failure at such load. Equipped with 3 or 6 stations to perform group tests as well as to conduct individual test at each station. The auto timing & locking functions provides highly accurate test results. The standard test plates & weights ensures the accuracy of the test results data.

Get Catalog
Standard roller 2000 ± 50 g
Testing stations 3
Dimension (L*W*H) tester 320×210×550 mm (3 stations)
Weight for stations 10 kg (3 stations)
Weight of the plates 1000 ± 3 g ( with triangle hook)
Test plate (L*W*H) 125×50×1.5 mm
Timing range 0 to 99 h 59 min 59 S
Power AC 220 V, 50 Hz
  • Equipped with standard test plates & weights
  • Microprocessor controlled system with PVC operation panel
  • LCD screen to set & view the test parameters
  • Equipped with auto timing and locking functions
  • 3 stations for group testing

Lasting adhesive tester has applications in plastic & packaging industry, stationary making industry.

Request Quote

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Whiteness meter TP-A11
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
Sample (size) length38×70 mm
Sample width
Measuring range(1-500) mN.m (divided into 7 small ranges)

Plastic Testing Instruments

Plastic Testing Instruments : Aging Oven TAO-A10
The maximum temperature300°C
Temperature fluctuationWithin ± 0.5°C
Temperature uniformityWithin ± 1°C
Plastic Testing Instruments : Vacuum Leak Tester TVLT-A10
Vacuum degree0 to 90 KPa
Accuracy1 % FS
Resolution0.1 KPa
Plastic Testing Instruments : Oxygen Index Tester TOIT-A10
Vacuum degree
Accuracy
Resolution0.1 % O2

Rubber Testing Instruments

Rubber Testing Instruments : Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control rangeRoom temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy± 0.3 ℃
Impact speed0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Rubber Testing Instruments : Three roll mill machine TRMM-A10
Mixed capacity0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature rangeRT to 300°C
Temperature control systemPID control
Rubber Testing Instruments : DIN abrasion tester TDAT-A10
Test arm weight2.5 N
Additional Loads2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler150 mm

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test306, 613, 1839 N

Soil Testing Instruments

Soil Testing Instruments : Soil nutrient tester TSNA-A10
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil nutrient tester TSNA-A11
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil Salinity tester TSST-A10
Salinity Measurement range0.00 to 19.99 ms/cm
Measuring accuracyEC ± 2% full scale
Temperature Measurement range-5 to 50°C