Automatic horizontal tensile tester TP-B12

Automatic horizontal tensile tester TP-B12 is adopted with pneumatic clamps to minimize the error by proper holding of the sample. With the advanced ARM technology, it has strong data processing functions. The large LCD touch screen interface makes it easy to operate the tester. Tensile tester can test tensile strength, tensile force, tensile energy absorption, fracture length, tensile index, 180° peel strength of paper, paperboard, plastic film & other non-metal materials.

Get Catalog
Sample (size) length 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width 15 mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Tensile strength velocity 1 to 399 mm/min (adjustable)
Tensile return velocity 1 to 399 mm/min (adjustable)
Sample loading Semi-automatic , can clamp the sample using hands
Dimension (L*W*H) 800 × 270 × 200 mm
Net weight 40 kg
Power supply 220 V ± 10 %, 50 Hz
  • Fully automatic or Semi-automatic sample loading
  • Adopted with imported noiseless motor, with precise controls
  • Large screen, display the tensile time, tensile strength, tensile curve
  • Equipped with RS232 interface, connection to PC for data transfer
  • Can get the measurement result directly
  • Easy to obtain & print the statistical results like average value, standard deviation, variable coefficient
  • High automation system with advanced parts
  • Variable tensile size & speed

Tensile horizontal tester is used in paper, paperboard, plastic film & other non-metal materials industry to test tensile strength, tensile force, tensile energy absorption, fracture & other parameters.

Request Quote

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Whiteness meter TP-A11
Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
Sample width
Measuring range
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
Sample (size) length38×70 mm
Sample width
Measuring range(1-500) mN.m (divided into 7 small ranges)

Plastic Testing Instruments

Plastic Testing Instruments : Aging Oven TAO-A10
The maximum temperature300°C
Temperature fluctuationWithin ± 0.5°C
Temperature uniformityWithin ± 1°C
Plastic Testing Instruments : Vacuum Leak Tester TVLT-A10
Vacuum degree0 to 90 KPa
Accuracy1 % FS
Resolution0.1 KPa
Plastic Testing Instruments : Oxygen Index Tester TOIT-A10
Vacuum degree
Accuracy
Resolution0.1 % O2

Rubber Testing Instruments

Rubber Testing Instruments : Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control rangeRoom temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy± 0.3 ℃
Impact speed0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Rubber Testing Instruments : Three roll mill machine TRMM-A10
Mixed capacity0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature rangeRT to 300°C
Temperature control systemPID control
Rubber Testing Instruments : DIN abrasion tester TDAT-A10
Test arm weight2.5 N
Additional Loads2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler150 mm

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
Preliminary test force98 N
Total test force588, 980, 1471 N
Brinell hardness test306, 613, 1839 N

Soil Testing Instruments

Soil Testing Instruments : Soil nutrient tester TSNA-A10
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil nutrient tester TSNA-A11
Measuring range0.001 to 9999
StabilityA (absorbency of light)
Linearity error
Soil Testing Instruments : Soil Salinity tester TSST-A10
Salinity Measurement range0.00 to 19.99 ms/cm
Measuring accuracyEC ± 2% full scale
Temperature Measurement range-5 to 50°C