Salt Spray Test Chamber LSSC-A12

Salt Spray Test Chamber LSSC-A12 is a nichrome heater comprised salt spray test chamber, designed as per ASTMB117, ISO9227 configurations, comes with 410 L of capacity and built-in 20 L salt solution tank with a brine mixing system. Features adjustable Atomizer tower and Spray nozzles spraying system with continuous/periodic spray, covered the entire working space to form a diffuse state. Equipped with PID controller, PT100 Ω / MV A-class sensor and timer, it offers complete recording of spray time with precise temperature and control. Designed with Glass fiber reinforced plastics housing, transparent resin lid and hydrostatic hood seal, it has sample holder of 6 round bars and 5 V-shaped grooves for different tests. With 31 L capacity of saturated air barrel protected against dry burning, this salt spray test chamber also offers protection against humidifier dry-combustion , over-temperature, over-current, water shortage and earth leakage.

Get Catalog
Testing room capacity 410 L
Temperature range Ambient to +60°C
Humidity range 95 to 98% RH
Temperature Fluctuation ± 0.5 ℃
Temperature Deviation ± 2.0 ℃
Spray deposition 1 to 2 ml / 80 cm2 .h
Spray type Continuous /Periodic
Spraying system Atomizer tower and Spray nozzle
Air preheating Saturated air barrel; 31 L
Heating element Nichrome heater
Salt fog collection Fog collector and Fog measure cylinder
Standard sample holder 8 round bars and 7 V-shaped grooves
Controller PID
Sensor PT100 Ω / MV A-class sensor
Housing Glass fiber reinforced plastics
Lid Transparent resin lid
Sealing Hydrostatic hood seal
Protection Humidifier Dry-combustion Protection;
Over-temperature Protection;
Over-current Protection;
Water Shortage Protection;
Earth leakage Protection
Maximum noise 65 dBA
Power supply 220 V 50 Hz 1 P
Water solution tank dimension (W×D×H) 350×180×320 mm
Internal dimension (W×D×H) 1100×750×500 mm
External dimension (W×D×H) 1900×920×1200 mm
Net weight 260 kg
Gross weight 310 kg
  • Nichrome heater comprised salt spray test chamber with 410 L capacity
  • Designed as per ASTMB117, ISO9227 configurations
  • Built-in 20 L salt solution tank with a brine mixing system
  • Adjustable Atomizer tower and Spray nozzles spraying system
  • Continuous/periodic spray to cover the entire working space to form a diffuse state
  • PID controller, PT100 Ω / MV A-class sensor and timer
  • Glass fiber reinforced plastics housing, transparent resin lid and hydrostatic hood seal
  • Sample holder of 8 round bars and 7 V-shaped grooves for different tests
  • 31 L capacity of saturated air barrel protected against dry burning, for preheating the air
  • Protection against humidifier dry-combustion , over-temperature, over-current, water shortage and earth leakage
  • Highly efficient, corrosion resistant with long service life

Salt spray test chamber is used to create and maintain the salt spray (fog) test environment, and test the anti-corrosion quality of all the materials surfaces after the rust-proof of painting, coating, electroplating, anodizing and rust-proof of greasing.

Request Quote

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Test Chamber : Drug Stability Test Chamber LDST-A20
Interior Volume100 L
Heat load1000 W
Temperature Range0℃ to 100 ℃
Drug Test Chamber : Drug Stability Test Chamber LDST-A21
Interior Volume225 L
Heat load1000 W
Temperature Range0℃ to 100 ℃
Drug Test Chamber : Drug Stability Test Chamber LDST-A22
Interior Volume500 L
Heat load1000 W
Temperature Range0℃ to 100 ℃

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber : Ozone Test Chamber LOC-A10
Diameter of holder (mm)
Length of each side (mm)
Temperature range0℃ ~ 100℃
Ozone Test Chamber : Ozone Test Chamber LOC-A11
Diameter of holder (mm)400
Length of each side (mm)180
Temperature range0℃ ~ 100℃
Ozone Test Chamber : Ozone Test Chamber LOC-A12
Diameter of holder (mm)600
Length of each side (mm)220
Temperature range0℃ ~ 100℃

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber : Plant Growth Chamber LPGC-A10
Chamber Volume300 L
Shelves3(PCS)
Display Resolution0.1 ℃
Plant Growth Chamber : Plant Growth Chamber LPGC-A11
Chamber Volume450 L
Shelves3(PCS)
Display Resolution0.1 ℃
Plant Growth Chamber : Plant Growth Chamber LPGC-A12
Chamber Volume800 L
Shelves3(PCS)
Display Resolution0.1 ℃

Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber : Salt Spray Test Chamber LSSC-A10
Testing room capacity110 L
Temperature rangeAmbient to +60°C
Humidity range95 to 98% RH
Salt Spray Test Chamber : Salt Spray Test Chamber LSSC-A11
Testing room capacity326 L
Temperature rangeAmbient to +60°C
Humidity range95 to 98% RH
Salt Spray Test Chamber : Salt Spray Test Chamber LSSC-A13
Testing room capacity780 L
Temperature rangeAmbient to +60°C
Humidity range95% to 98% RH

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Sand Test Chamber : Sand and Dust Test Chamber LSC-A10
Temperature rangeAmbient to + 50 ℃
Relative Humidity< 30 % RH
Normal wire diameter50 um
Sand Test Chamber : Sand and Dust Test Chamber LSC-A11
Temperature rangeAmbient to + 50 ℃
Relative Humidity< 30 % RH
Normal wire diameter50 um
Sand Test Chamber : Sand and Dust Test Chamber LSC-A12
Temperature rangeAmbient to + 50 ℃
Relative Humidity< 30 % RH
Normal wire diameter50 um

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Temperature and Humidity Test Chamber : Temperature and Humidity Test Chamber LTHC-A10
Capacity50 L
Temperature range(- 20 °C) to 150 °C
Low typeI – 40 °C, II – 70 °C
Temperature and Humidity Test Chamber : Temperature and Humidity Test Chamber LTHC-A11
Capacity80 L
Temperature range(- 20 °C) to 150 °C
Low typeI – 40 °C, II – 70 °C
Temperature and Humidity Test Chamber : Temperature and Humidity Test Chamber LTHC-C10
Interior Volume700 L
Heat load1000 W
Temperature Range10℃ to +50 ℃

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber : UV Test Chamber LUVC-A10
Temperature Range
Humidity range
Testing Time
UV Test Chamber : UV Test Chamber LUVC-A20
Temperature RangeRT + 100 °C ~ 850 °C
Humidity rangeAt 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %
Testing Time20 hours
UV Test Chamber : UV Test Chamber LUVC-A21
Temperature RangeRT + 100 °C ~ 630 °C
Humidity range30 % ~ 85 % RH
Testing Time20 hours

Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Xenon Test Chamber : Xenon Test Chamber LXC-A22
Temperature RangeRT+50℃ to 70℃
Temperature Fluctuation±3℃
Cooling WayAir-cooled
Xenon Test Chamber : Xenon Test Chamber LXC-A10
Bandwidth Measurement (nm)280 ~ 800
Specimen Capacity (pcs)28
Specimen holder size (mm)80 × 15
Xenon Test Chamber : Xenon Test Chamber LXC-A11
Bandwidth Measurement (nm)300 - 420
Specimen Capacity (pcs)34
Specimen holder size (mm)80 × 15