Distillation Tester (low temperature Double units) LDT-A16

Distillation Tester (low temperature Double units) LDT-A16 is a double-units distillation tester in which the minimum temperature of the condenser pipe can reach 0℃. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products at Barometric Pressure) as per ASTM D86.

Get Catalog
Graduated flasks 100 ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature controlling accuracy ± 0.5 °C
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Division value 1°C
Scale division 1 ml
Inner diameter of electric furnace φ32 mm, φ38 mm
Outer diameter of electric furnace φ50 mm
Dimension 830 x 610 x 870 mm
Heating power system 1000 W × 2
Total power consumption ≤ 5000 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Immersion rod type thermometer
  • Ideal distillation tester under low temperature condition
  • Compressor used as refrigeration device
  • LED display

It is used to determine natural gasoline, vehicle gasoline, special boiling point solvent, naphtha, diesel oil, distillate and similar petroleum products.

Request Quote

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter : Automatic Bomb Calorimeter LABC-A10
Calorimeter typeIsoperibol
Temperature range5 to 40°C
Measurement range5 to 40 MJ/ kg
Automatic Bomb Calorimeter : Automatic Bomb Calorimeter LABC-A11
Calorimeter typeIsoperibol
Temperature range5 to 40°C
Measurement range5 to 40 MJ/ kg
Automatic Bomb Calorimeter : Automatic Bomb Calorimeter LABC-B10
Calorimeter typeIsoperibol
Oxygen fillingFully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume250 ml

Octane Number & Cetane Number Tester

Octane Number & Cetane Number Tester : Octane Number and Cetane Number Tester LOCT-A10
 Measuring Range For Aviation Gasoline86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor VehiclesNational standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For EthanolE93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Octane Number & Cetane Number Tester : Portable Octane Number and Cetane Meter LOCT-A20
Measurement itemmotor gasoline and diesel
measurement unit of octane is ON40 to 120
Permissible error of octane± 0.5 max

Acid and Alkali Tester

Acid and Alkali Tester : Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask100 ml,50 ml
Conical flask100ml
Separatory funnel250ml
Acid and Alkali Tester : Acid Number and Acidity Tester LAAT-A11
Graduated flask
Conical flask
Separatory funnel
Acid and Alkali Tester : Acid Number Tester LAAT-A12
Graduated flask
Conical flask
Separatory funnel

Aniline Test Equipment

Aniline Test Equipment : Aniline Point Tester LAPT-A10
Measurement rangeRoom temperature ~ 150°C
Stirring speed0 ~ 1200 r / min
Heating power25 W
Aniline Test Equipment : Aniline Point Tester LAPT-A11
Measurement range
Stirring speed
Heating power

Closed Cup Flash Point Tester

Closed Cup Flash Point Tester : PMCC Flash Point Tester LCFP-A10
Ambient temperature≤ 35 °C
Relative humidity≤ 85 %
Ignition Mode
Closed Cup Flash Point Tester : Automatic PMCC Flash Point Tester LCFP-A11
Ambient temperature10 °C ~ 40 °C
Relative humidity≤ 80 %
Ignition Mode
Closed Cup Flash Point Tester : Automatic PMCC Flash Point Tester LCFP-A13
Ambient temperature10 °C ~ 40 ℃
Relative humidity≤ 80 %
Ignition Modeelectron igniter / gas flame

Demulsibility Characteristics Tester

Demulsibility Characteristics Tester : Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %
Timing range1 s to 9 min 59 s
Demulsibility Characteristics Tester : Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %
Timing range

Distillation Tester

Distillation Tester : Automatic Distillation Apparatus LADA-A10
Heating power2 kW
Cooling power0.5 kW
Steam temperature0 to 400℃
Distillation Tester : Benzene Distillation Tester (Low Temperature) LDT-A11
Ambient temperature-10°C to 35°C
Relative humidity≤ 85 %
ThermometerEach one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Distillation Tester : Distillation Tester Dual Units LDT-A15
Graduated flasks100 ml
Scale division of graduated flask1ml
Distillation flask125 ml

Dropping Point Tester

Dropping Point Tester : Dropping Point Tester (Oil Bath) LDPT-A10
Beaker quantity600 ml
Ambient temperature(-10) °C ~ 40 °C
Relative humidity≤ 85 %
Dropping Point Tester : Dropping Point Tester (Air bath) LDPT-A11
Beaker quantity
Ambient temperature≤ 35 ℃
Relative humidity≤ 85 %

Engler Viscometer

Engler Viscometer : Engler Viscometer LEV-A10
Graduated Flask200 ± 0.2 ml
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C
Engler Viscometer : Engler Viscometer LEV-A11
Graduated Flask100 ml
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C
Engler Viscometer : Engler Viscometer LEV-B10
Graduated Flask200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C

Existent Gum Tester

Existent Gum Tester : Existent Gum Tester LEGT- B30
Bath typeOil bath
Bath capacity5000 ml ± 50 ml
Ambient temperatureRoom temperature to 35 °C
Existent Gum Tester : Existent Gum Tester LEGT- B31
Bath type
Bath capacity
Ambient temperature
Existent Gum Tester : Existent Gum Tester LEGT- B32
Bath type
Bath capacity
Ambient temperature

Kinematics Viscometer

Kinematics Viscometer : Kinematics Viscometer LKV-A10
Ambient temperature15 to 35°C
Relative humidity≤ 85%
Capillary viscometer6 capillary Pinkevitch viscometer tubes
Kinematics Viscometer : Kinematics Viscometer LKV-A11
Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer11 pieces
Kinematics Viscometer : Kinematics Viscometer LKV-A12
Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer11 pieces

Low Temperature Tester

Low Temperature Tester : Freezing Point Tester LLTT-A11
Freezing point range-54°C to 2°C
Cold bath measurement temperature range-70° to 20°C
Temperature controlling accuracy±0.5°C
Low Temperature Tester : Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
Measurement range
Temperature controlling accuracy
Refrigeration system
Low Temperature Tester : Solidifying Point Tester LLTT-A13
Measurement range
Temperature controlling accuracy± 0.5 ℃
Refrigeration systemNew-type refrigeration compressor

Open Cup Flash Point Tester

Open Cup Flash Point Tester : Open Cup Flash Point Tester LOFP-A10
Thermometer0 ℃ ~ 360 °C
Scale Division1 °C
Spout Aperture
Open Cup Flash Point Tester : Cleveland Open Cup Flash Point Tester LOFP-A11
Thermometer6 ℃ ~ 400 ℃
Scale Division2 °C
Spout Aperture0.6 ~ 0.8 mm
Open Cup Flash Point Tester : Automatic COC Flash & Fire Point Tester LOFP-B10
Thermometer
Scale Division
Spout Aperture

Other Instrument

Other Instrument : Mechanical Impurity Tester (Weight Method) LMIT-A21
Light source
Temperature of grinding milk white light bulb
Light hole( Φ14)
Other Instrument : Wax Oil Content Tester LWCT-A22
Light source
Temperature of grinding milk white light bulb
Light hole( Φ14)
Other Instrument : Insulating Oil Breakdown Voltage Tester LIBT-A23
Light source
Temperature of grinding milk white light bulb
Light hole( Φ14)

Oxidation Stability Tester

Oxidation Stability Tester : Gasoline Oxidation Stability Tester LOST-D13
TypeCompact; Desktop
DesignIntegrated
BathMetal bath (without water usage)
Oxidation Stability Tester : Oxidation Stability Tester (Lubricating Grease) LOST-D20
Temperature RangeAmbient to 150℃
Temperature Precision± 0.1°C
Test Unit2 units

Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter : Oxygen Bomb Calorimeter LBC-C21
Heat capacity
Temperature measurement range
Temperature controlling range10 ℃ ~ 35 ℃
Oxygen Bomb Calorimeter : Oxygen Bomb Calorimeter LBC-C22
Heat capacity
Temperature measurement range10 ~ 35 ℃
Temperature controlling range
Oxygen Bomb Calorimeter : Oxygen Bomb Calorimeter LBC-C20
Heat capacity14000 ~ 15000 J / K
Temperature measurement range10 ~ 35 ℃
Temperature controlling range

Residue Carbon

Residue Carbon : Carbon Residue Tester (Ramsbottom) LRCT-B20
Coking furnaceMetal furnace
Heating modeElectric heating
Test unit5 units
Residue Carbon : Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
Porcelain crucible30 ml
Inner iron crucible75 ml
Outer iron crucible190 ml

Rust and Corrosion Tester

Rust and Corrosion Tester : Copper Strip Corrosion Tester LRCT-A13
Sample hole4 pieces
Sample quantity4 to 12 pieces
Ambient temperatureRoom temperature to 35 °C
Rust and Corrosion Tester : Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10
Sample hole2 pieces
Speed of stirring motor1400 rpm
Ambient temperature10 to 35°C
Rust and Corrosion Tester : Lubricating Oil Rust Characteristics Tester LRCT-A11
Sample hole4 pieces
Speed of stirring motor1400 rpm
Speed for sample stirring1000 ± 50 rpm

Sulphur Content Tester

Sulphur Content Tester : X-ray Fluorescence Sulfur in Oil Analyzer LST-A10
Air flow rate
Max. Preset time
Chamber diameter of oven
Sulphur Content Tester : Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11
Air flow rateNot less than 150 L / h
Max. Preset time99 min 59 s (100 min)
Chamber diameter of ovenΦ22 mm

Vapor Pressure

Vapor Pressure : Vapor Pressure Tester (REID METHOD)  LVPT-C10
Test bomb
Operation temperature of water bathRT ~ 90 °C
Bath temperature
Vapor Pressure : Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
Test bombTwo samples or a group of parallel samples
Operation temperature of water bath
Bath temperature37.8 °C

Water Content Tester

Water Content Tester : Coulometric Karl Fischer Titrator LWT-A30
Ambient Temperature10°C to 35°C
Measurement Range0 to 100 mg
Resolution0.1 µg
Water Content Tester : Coulometric Karl Fischer Titrator LWT-A31
Maximum current400 mA
Measurement range3 µg to 9999.9 µg
Resolution0.1 µg
Water Content Tester : Water Content Tester LWT-A10
Ambient Temperature Range≤ 35°C
Relative Humidity≤ 85%
Distillation Flask

Penetrometer

Penetrometer : Penetrometer LMPT-A10
Measurement range0 to 600 penetration scale
Timing controller5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy± 0.1 seconds
Penetrometer : Penetrometer LMPT-A11
Measurement range0 to 600 penetration scale
Timing controller5 sec or 60 sec
Time accuracy± 0.1 seconds
Penetrometer : Penetrometer LMPT-A12
Penetrometer0 to 600 penetration scale, 5 sec or 60 sec, ± 0.1 seconds, 0.1 penetration, ± 1 penetration, 2.5 ± 0.05 g, 700 × 400 × 750 mm, 30 kg
Circulatory Water Bath3.5 L, 5 °C to 60 °C, ± 0.1 °C, 3 L/minute, 2 m, 1200 W, AC 220V ± 10 %, 50 Hz, 600 × 400 × 650 mm, 40 kg