FTIR Spectrometer LIR-B10 offers gold coated reflecting mirrors to cover maximum light throughput with detection sensitivity with multilayer Ge coated KBr beam splitter specification, aluminum based cast design layout structure, and high intensity, long lasting air cooled infrared source. Designed with 7800 cm-1 to 350 cm-1 spectral range with high S: N ratios of up to 20,000:1. This FTIR executes operations such as scanning, data manipulation, quantitation, reporting, saving, user administration, and more. Features advance FTIR software workstation, adjusted for all versions of windows operating system with specialized IR libraries, real-time device status analysis, modular platform strategy, FDA CFR 21 compliance auto software updating system, Sensitivity detector DLATGS. Equipped with Cube-corner Michelson interferometer, the highly sensitive optical system with collectively patented fixing mirror alignment tools.
Get Catalog| Spectral Range | 7800 cm-1 to 350 cm-1 |
| Resolution | 0.85 cm-1 |
| Wave number precision | ± 0.01 cm-1 |
| Scanning speed | Microprocessor control, different scanning speed selectable |
| Signal to Noise ratio | 20,000:1( RMS value 2100-1 to 2000-1 ) |
| Beam Splitter | Ge coated KBr |
| Infrared Source | High intensity, long lasting, air- cooled IR source |
| Detector | DLATGS |
| Data System | Compatible computer |
| Dimension | 520 × 435 × 255 mm |
| Weight | 24 kg |
| Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
| Interferometer | Cube-corner Michelson interferometer |
| Wave number Accuracy | ± 0.01 cm-1 |
| Communication | Ethernet interface |
| Status Diagnose | Power on self-check |
| Certification | FDA CFR 21 Compliance |
FTIR Spectrometer has wide applications in the field of science research examination, quality control production, testing and detection in various field.
Request Quote

| Wavelength range ( 3600 lines / mm ) | 180 to 500 nm |
| Wavelength range ( 2400 lines / mm ) | 180 to 800 nm |
| Temperature | 20 ~ 28 °C |

| Monochromator Specifications | Czerny turner, ≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating), 1000 mm, huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area, 195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating |
| Solid State Power Specifications | 27.12 MHz Frequency stability: < 0.05%, Scott double pass spray chamber, 800 W to 1600 W, adjustable with power efficiency more than 65%, ≤ 0.05%, 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter) |
| Technical Specifications | Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%, short-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2%, 5 to 8 elements / min, 1ppb to 10ppb |

| Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
| Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
| Range | Simultaneous detector |