Portable Multiple Gas Detector LPMG-A10

Portable Multiple Gas Detector LPMG-A10 with compact handheld design, simultaneously detects contents of four different gases namely H2S, CO, O2, CH4. Large easy to read lattice TFT display shows all real time detection values of gases. Used in field detection of multiple gases for quality testing and research purpose.

Get Catalog
Sampling Method Diffusion
Working conditions
Temperature -20 to 50°C
Pressure 0.9 to 1.1 (standard atmospheric pressure)
Humidity 10 to 95 % RH (no dew condensation)
Explosion proof grade Exia II CT3
Protection grade IP65
Charging time 4 to 6 h
Working time of battery > 8 h (non-alarm state)
Type of battery Lithium battery
Length of Pump pipe < 1 meter
Measurement principle of sensor Electrochemical, catalytic combustion
Power supply Lithium battery (DC 3.7V, 2400mAh)
Dimension (host machine) 85 × 153 × 50 mm
Dimension (hand shake of gas pump) 45 × 239 × 28 mm
Weight (host machine) About 300 g
Weight (hand shake of gas pump) About 80 g
HS Code 9027100090
  • Portable, lightweight design
  • Save power by adjusting back light brightness
  • Electrochemical, catalytic combustion, imported sensor
  • Can set Upper/Lower alarm limits for better operations
  • Alarm with LED buzzer, vibration alerts when gas spikes are detected
  • Automatic battery detection (under-voltage indication)
  • Stores test memory data, alarm data

Used for simultaneous field detection of H2S, CO, O2, CH4 across mining, environmental industry, waste management plants, petroleum testing units, gas and chemical industry.

Request Quote

Gas Detectors

Gas Detectors : Handheld C2H4 Ethylene Gas Detector LEGD-A10
SamplingWith internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
GasEthylene C2H4
Measure Range0 to 1000 ppm
Gas Detectors : Portable 2 in 1 gas detector LPTG-A10
Sampling methodDiffusion
Sensor typeCO2: solid electrolyte sensor, O2:electrochemical sensor
Detection rangeCO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Gas Detectors : Portable infrared gas detector LIGD-A10
Measurement principleNon-dispersive infrared  (NDIR)
Gas DetectedSF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
Detection Uncertainty

Digital Differential Pressure Meter

Digital Differential Pressure Meter : Digital Differential Pressure Meter LDPM-A10
Measuring range0 ∼ 125 Pa
Accuracy0 ± 0.2 Pa (liner error) ± 1 %
Repeatability
Digital Differential Pressure Meter : Digital Differential Pressure Meter LDPM-A20
Measuring range± 500 Pa
Accuracy
Repeatability± 0.2 % FS

Multifunctional Environmental Meter

Multifunctional Environmental Meter : 6 in 1 Multifunctional Environmental Meter LMEM-A10
Temperature Measurement Range-10℃ to 60℃
Temperature Resolution0.1°C
Temperature Accuracy± 1.5℃
Multifunctional Environmental Meter : Floor Balance LFRB-A20
Capacity50 kg
Accuracy1 g
Speed1 s