Analytical HPLC-A7835

Analytical HPLC-A7835 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.

Get Catalog
Pump Specifications
Model No HPP-B1
Flow rate range 0.0001 to 10 ml / min
Maximum pressure 42 MPa , 0 to 5 ml / min
Column size 4.6 × 250 mm
Sample size 5 μm
Pressure pulsation ≤ 1.5 % at 10 MPa
Flow rate accuracy ± 0.2 % at 1 ml / min
Flow rate repeatability % ≤ 0.15
Gradient accuracy % ± 2
Gradient repeatability % ≤ 0.2
Dimension 450 × 260 × 190 mm
Power supply 90 V to 240 V
Weight 11.2 kg
Detector Specifications
Model No HPD-B2
Wavelength range 190 to 800 nm
Wavelength accuracy ± 0.75 nm
Wavelength repeatability 0.2 nm
Band width 8 nm
Optical path 10 nm
Deuterium lamp 190 to 400 nm
Tungsten lamp 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.5 × 10 -5
Baseline drift ( Static ) Au / h ≤ 1.5 x 10 -4
Minimum detection limit ≤ 4 x 10 -8
Power 100 W
Power supply 90 V / 50 to 60 Hz
Dimension 460 × 260 × 190 mm
Weight 9.2 kg
  • Compression compensation ensuring gradient repeatability
  • Low pressure gradient
  • Detector ( Deuterium or tungsten lamp )
  • Simultaneous working of deuterium and tungsten lamp
  • Automatic sample injector ( Autosampler )
  • External pump control by panel or computer software
  • Auto save last detected records by the detector
  • 10 point calibration pump for linear pressure control
  • Error alarm function for over pressure ,under pressure and leakage

Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis

Request Quote

Standard HPLC

Standard HPLC : HPLC system LHLC-A10
High pressure pumpSingle pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-A11
High pressure pumpTwo sets of pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increments)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11
High pressure pumpHigh pressure constant-current infusion pump
Infusion WayMicro volume series dual-piston
Infusion pressure0 - 9999 Psi

Analytical HPLC

Analytical HPLC : Analytical HPLC System LAHS-A10
Pump specificationQuaternary Low Pressure Pump, 0.001 to 10.000 ml/min, in 0.001ml increments, ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa), RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa), 63 MPa, ≤ ± 3.0 %, ≤ 0.1 MPa, 0 to 100 %, ≤ 0.3 % RSD
UV/VIS Detector190 to 800 nm, ≤ 0.1 nm, ≤ ± 1.0 nm, 6 nm, 0.0 s to 5 s, ≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s), ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min), 10 mm(analytical cell), Deuterium Lamp and Tungsten Lamp
Data-processing WorkstationSystem contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA
Analytical HPLC : Analytical HPLC System LAHS-B10
High Pressure Constant Flow Pump1 set, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W
UV/Visible Detector190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 2 × (600 × 410 × 300 mm, 54 kg
Analytical HPLC : Analytical HPLC System LAHS-B11
High Pressure Constant Flow Pump2 sets, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W
UV/Visible Detector190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 3 × (600 × 410 × 300 mm, 75 kg