Analytical HPLC System LAHS-A10 features Quaternary Low Pressure Pump with 0.001-10 ml/min pump flow rate. Incorporated UV-Vis detector with a range of 190 to 800 nm that examines sample absorption at different wavelengths and a high pressure pump providing continuous stable flow. This HPLC system offers high speed accuracy, resolving power, detection, quantification, convenience and applicability to new sample types.
Get Catalog| Pump specification |
|
||||||||||||||||||
| UV/VIS Detector |
|
||||||||||||||||||
| Data-processing Workstation |
System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA |
||||||||||||||||||
| System Kits |
1 Set Combined A/D converters Combined vacuum degasser and 4 channel |
||||||||||||||||||
| Power Supply | AC 110 /220 V ±1 0 %, 50/60 Hz | ||||||||||||||||||
| Dimension | 710 × 583× 500mm; 770 × 450 × 700 mm | ||||||||||||||||||
| Weight | 156 kg |
High Performance Liquid Chromatography system has been widely used in Research and Development, pharmaceutical, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity.
Request Quote

| High pressure pump | Single pump |
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increment) |
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |

| High pressure pump | Two sets of pump |
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increments) |
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |

| High Pressure Constant Flow Pump | 1 set, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W |
| UV/Visible Detector | 190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 2 × (600 × 410 × 300 mm, 54 kg |

| High Pressure Constant Flow Pump | 2 sets, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W |
| UV/Visible Detector | 190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 3 × (600 × 410 × 300 mm, 75 kg |

| Pump Specifications | HPP-B1, 0.0001 to 10 ml / min, 42 MPa , 0 to 5 ml / min, 4.6 × 250 mm, 5 μm, ≤ 1.5 % at 10 MPa, ± 0.2 % at 1 ml / min, ≤ 0.15, ± 2, ≤ 0.2, 450 × 260 × 190 mm, 90 V to 240 V, 11.2 kg |
| Detector Specifications | HPD-B2, 190 to 800 nm, ± 0.75 nm, 0.2 nm, 8 nm, 10 nm, 190 to 400 nm, 400 to 800 nm, ≤ ± 0.5 × 10 -5, ≤ 1.5 x 10 -4, ≤ 4 x 10 -8, 100 W, 90 V / 50 to 60 Hz, 460 × 260 × 190 mm, 9.2 kg |
Copyright @ labtrononline.com