Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has isocratic kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.

Get Catalog
High Pressure Constant Flow Pump
Double plunger reciprocating pump 1 set
Flow range 0.001 to 10.00 mL/min
Setting step size 0.001 mL/min
Flow accuracy ≤ ± 0.3 %
Flow stability RSD ≤ 00.1 %
Maximum pressure 42 MPa
Display pressure error ≤ 1.0 %
Pressure fluctuation ≤ 1.0 %
Power consumption 80 W
UV/Visible Detector
Wavelength range 190 to 700 nm
Wavelength repeatability ± 0.1 nm
Band width 8 nm
Response time 0 to 4.9 seconds
Linearity range 1.8 AU (5 %)
Baseline Noise ≤ ± 1 × 10-5AU
Baseline drift ≤ 2.0 × 10-4AU/h
Minimum detectable concentration 4.0 × 10-9 g/mL
Detector cell Optical path: 10 mm
Volume: 10 µL
Light source Deuterium lamp
Power consumption 100 W
Voltage AC 110 V/ 220 V ± 10 %, 50/60 Hz
Packing Dimensions (W × D × H) 600 × 440 × 380 mm
2 × (600 × 410 × 300 mm
Gross weight 54 kg
  • Double plunger reciprocating pump system
  • Isocratic system kits
  • Sample injector: 1 set
  • Deuterium lamp light source
  • Separate workstation
  • LCD display for value observation
  • Front mounted self-locking switch
  • Output: USB port
  • Compact and easy to install

Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

Request Quote

Standard HPLC

Standard HPLC : HPLC system LHLC-A10
High pressure pumpSingle pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-A11
High pressure pumpTwo sets of pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increments)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11
High pressure pumpHigh pressure constant-current infusion pump
Infusion WayMicro volume series dual-piston
Infusion pressure0 - 9999 Psi

Analytical HPLC

Analytical HPLC : Analytical HPLC System LAHS-A10
Pump specificationQuaternary Low Pressure Pump, 0.001 to 10.000 ml/min, in 0.001ml increments, ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa), RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa), 63 MPa, ≤ ± 3.0 %, ≤ 0.1 MPa, 0 to 100 %, ≤ 0.3 % RSD
UV/VIS Detector190 to 800 nm, ≤ 0.1 nm, ≤ ± 1.0 nm, 6 nm, 0.0 s to 5 s, ≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s), ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min), 10 mm(analytical cell), Deuterium Lamp and Tungsten Lamp
Data-processing WorkstationSystem contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA
Analytical HPLC : Analytical HPLC System LAHS-B11
High Pressure Constant Flow Pump2 sets, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W
UV/Visible Detector190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 3 × (600 × 410 × 300 mm, 75 kg
Analytical HPLC : Analytical HPLC-A7835
Pump SpecificationsHPP-B1, 0.0001 to 10 ml / min, 42 MPa , 0 to 5 ml / min, 4.6 × 250 mm, 5 μm, ≤ 1.5 % at 10 MPa, ± 0.2 % at 1 ml / min, ≤ 0.15, ± 2, ≤ 0.2, 450 × 260 × 190 mm, 90 V to 240 V, 11.2 kg
Detector SpecificationsHPD-B2, 190 to 800 nm, ± 0.75 nm, 0.2 nm, 8 nm, 10 nm, 190 to 400 nm, 400 to 800 nm, ≤ ± 0.5 × 10 -5, ≤ 1.5 x 10 -4, ≤ 4 x 10 -8, 100 W, 90 V / 50 to 60 Hz, 460 × 260 × 190 mm, 9.2 kg