This HPLC system is equipped with high-pressure constant-current pump and UV detector. Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors helps in identification of samples and elutes that are colourless, odourless in nature. There is auto boot detection function available in this HPLC system.
Get Catalog| High pressure pump | Single pump | ||||||||||||||||||
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increment) | ||||||||||||||||||
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) | ||||||||||||||||||
| Flow rate precision | RSD < 0.06 % | ||||||||||||||||||
| Pulsation | ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa) | ||||||||||||||||||
| Qualitative analysis | RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent) | ||||||||||||||||||
| Quantitative repeatability | RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent) | ||||||||||||||||||
| Flow rate setting error | Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature) | ||||||||||||||||||
| Mixing accuracy | ± 1 % | ||||||||||||||||||
| Mixing precision | ± 0.2 % | ||||||||||||||||||
| Size (W × H × D) | 450 × 300 × 160 mm | ||||||||||||||||||
| UV Detector |
|
The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.
Request Quote

| High pressure pump | Two sets of pump |
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increments) |
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |

| High pressure pump | High pressure constant-current infusion pump |
| Infusion Way | Micro volume series dual-piston |
| Infusion pressure | 0 - 9999 Psi |

| Pump specification | Quaternary Low Pressure Pump, 0.001 to 10.000 ml/min, in 0.001ml increments, ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa), RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa), 63 MPa, ≤ ± 3.0 %, ≤ 0.1 MPa, 0 to 100 %, ≤ 0.3 % RSD |
| UV/VIS Detector | 190 to 800 nm, ≤ 0.1 nm, ≤ ± 1.0 nm, 6 nm, 0.0 s to 5 s, ≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s), ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min), 10 mm(analytical cell), Deuterium Lamp and Tungsten Lamp |
| Data-processing Workstation | System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA |

| High Pressure Constant Flow Pump | 1 set, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W |
| UV/Visible Detector | 190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 2 × (600 × 410 × 300 mm, 54 kg |

| High Pressure Constant Flow Pump | 2 sets, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W |
| UV/Visible Detector | 190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 3 × (600 × 410 × 300 mm, 75 kg |