This HPLC system is incorporated with advanced high pressure injection technique. The detector is equipped with 24 bits AD transducer to assure low noise, low drift and high sensibility. This HPLC system can conveniently change the sample input volume. It comes with dual piston reciprocating and series pump for consistent and stable flow.
Get Catalog| High pressure pump | High pressure gradient pump | ||||||||||||||
| Peak operating pressure | 45 MPa, Stainless steel pump | ||||||||||||||
| Pressure | ± 0.02 MPa | ||||||||||||||
| Flow rate range | 0.001 - 9.999 mL / min | ||||||||||||||
| Flow rate precision | ± 5 % | ||||||||||||||
| Flow rate repeatability | RSD ≤ 0.1 % | ||||||||||||||
| Power | 220V ± 10 %, 50 Hz, 250 W | ||||||||||||||
| Size (W × H × D) | 520 × 420 × 160 mm | ||||||||||||||
| UV Detector |
|
||||||||||||||
| Automatic Injector |
|
||||||||||||||
| Column oven |
|
||||||||||||||
| Overall Instrument |
|
This gradient HPLC system has multiple applications in medicine analysis, detection of protein content of food, environmental analysis, oil and chemical analysis and in scientific research studies.
Request Quote

| High pressure pump | Single pump |
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increment) |
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |

| High pressure pump | Two sets of pump |
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increments) |
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |

| Pump specification | Quaternary Low Pressure Pump, 0.001 to 10.000 ml/min, in 0.001ml increments, ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa), RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa), 63 MPa, ≤ ± 3.0 %, ≤ 0.1 MPa, 0 to 100 %, ≤ 0.3 % RSD |
| UV/VIS Detector | 190 to 800 nm, ≤ 0.1 nm, ≤ ± 1.0 nm, 6 nm, 0.0 s to 5 s, ≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s), ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min), 10 mm(analytical cell), Deuterium Lamp and Tungsten Lamp |
| Data-processing Workstation | System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA |

| High Pressure Constant Flow Pump | 1 set, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W |
| UV/Visible Detector | 190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 2 × (600 × 410 × 300 mm, 54 kg |

| High Pressure Constant Flow Pump | 2 sets, 0.001 to 10.00 mL/min, 0.001 mL/min, ≤ ± 0.3 %, RSD ≤ 00.1 %, 42 MPa, ≤ 1.0 %, ≤ 1.0 %, 80 W |
| UV/Visible Detector | 190 to 700 nm, ± 0.1 nm, 8 nm, 0 to 4.9 seconds, 1.8 AU (5 %), ≤ ± 1 × 10-5AU, ≤ 2.0 × 10-4AU/h, 4.0 × 10-9 g/mL, Optical path: 10 mm Volume: 10 µL, Deuterium lamp, 100 W, AC 110 V/ 220 V ± 10 %, 50/60 Hz, 600 × 440 × 380 mm 3 × (600 × 410 × 300 mm, 75 kg |