Atomic Absorption Spectrophotometer LAAS-A13

Flame Atomic Absorption Spectrophotometer LAAS-A13 is a microprocessor controlled instrument based on analysis of metal ions by flame and graphite furnace atomizer with their absorption at wavelength of 190 to 900 nm. Czerny-Turner monochromator and variance of bandwidth provides user flexibility. It is provided with deuterium hollow cathode lamp to exclude interference of molecular absorption and Titanium Burner to increase the analysis efficiency and precision of flame. Its double beam radiation sources enables good basic line stability. Graphic analysis system provides data on analysis of entire process e.g. measured value, temperature, procedures, time, etc. It has great applications in research, medicine, environmental science and other industries.

Get Catalog
Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Baseline stability ≤ 0.002 Abs / 30 min
Characteristic concentration of copper 0.02 μg / ml / 1 %
Detection limit of copper 0.004 μg / ml
Measurement Repeatability 0.005
Grating 1800 lines / mm
Inflamer All-metal titanium burner
Atomizer Efficient glass atomizer
Lamp stand 8 lamps automatic turret, automatic alignment
D2 Background calibration ability 1 A ≤ 30 times correction ability
Dimensions 700 × 550 × 450 mm
Net weight 75 Kg
Power supply 220 V ± 22 V AC
Acetylene air burner 100 mm
Ignition dynamic baseline drift ≤ 0.006 Abs / 30 min
Characteristic viscocity ≤ 0.025 μg / ml / 1 %
Standard deviation of the accuracy ≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml)
Protection system Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner
  • Integrated flame/graphite furnace atomization system, changeable with flame emission burner
  • Turret for 8 pre-aligned Hollow Cathode Lamps fitted with pre-heating, and individual pre-centred lamps
  • PID and Dual curve mode light-controlled temperature control technique ensures fast heating and analytical sensitivity
  • Fully automated wavelength scanning and peak searching
  • Advance software for complete parameter settings
  • Reliable fully automatic graphite furnace analysis
  • Alarm feature to protect fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system
  • Analysis of elements by flame absorption method and emission method
  • Strong database system which possesses more than 500 data self-storage
  • Results printed as parameter, data result and diagram

It is suitable to analyse trace amount of element from mixture, also in forensics and chemistry, biological science to detect toxic elements from blood and drug samples.

Request Quote

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer : Double Beam UV-Vis Spectrophotometer LUS-B10
Wavelength Range190 to 1100 nm
Spectral Bandwidth1.8 nm
Optical SystemDouble beam
Double Beam UV/Vis Spectrophotometer : Double Beam UV-Vis Spectrophotometer LUS-B13
Wavelength Range190 to 1100 nm
Spectral Bandwidth1.0 nm
Optical SystemDouble beam
Double Beam UV/Vis Spectrophotometer : Double Beam UV-Vis Spectrophotometer LUS-B11
Wavelength range190 to 1100 nm
Spectral bandwidth1.8 nm
Optical systemDouble beam; 1200 lines/mm grating

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer : Nano Spectrophotometer LNS-B10
Wavelength260 nm and 280 nm; Fixed
Spectral resolution≤ 8 nm
Path length0.5 mm
Nano Spectrophotometer : Nano Spectrophotometer LNS-A10
Cuvette
Temperature
PC
Nano Spectrophotometer : Nano Spectrophotometer LNS-A21
Cuvette
Temperature
PC

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Visible Spectrophotometer : Single Beam UV/Vis Spectrophotometer LUS-A50
Wavelength range190 to 1100 nm
Spectral bandwidth2 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Vis Spectrophotometer LUS-A51
Wavelength range190 to 1100 nm
Spectral bandwidth1 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Vis Spectrophotometer LUS-A52
Wavelength range190 to 1100 nm
Spectral bandwidth0.5/1/2/4/5 nm
Wavelength Accuracy± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer : Vis Spectrophotometer LVS-A10
Wavelength Range330 to 1000 nm
Setting Wavelength
Spectral Bandwidth5 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-A11
Wavelength Range335 ~ 1000 nm
Setting Wavelength
Spectral Bandwidth4 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-B10
Wavelength Range325 ~ 1000 nm
Setting WavelengthAutomatic
Spectral Bandwidth2 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A11
Monochromator
Wavelength range190 - 900 nm
Spectral Bandwidth0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A20
Monochromator
Wavelength range180 - 900 nm
Spectral Bandwidth0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A21
Monochromator
Wavelength range180 – 900 nm
Spectral Bandwidth0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)

Table Top Spectrophotometer

Table Top Spectrophotometer : Table Top Spectrophotometer LTS-A15
Wavelength Range400 nm to 700 nm
Wavelength Interval10 nm
SensorHigh sensitivity silicon photodiode
Table Top Spectrophotometer : Table Top Spectrophotometer LTS-A16
Wavelength Range360 nm to 780 nm
Wavelength Pitch10 nm
SensorSilicon Photodiode Array
Table Top Spectrophotometer : Table top spectrophotometer LTS-A10
Illumination systemd/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere40 mm, alvan diffused reflection surface coating
Illumination light sourceCLED

Portable Spectrophotometer

Portable Spectrophotometer : Portable Spectrophotometer LSP-A30
Illumination45/0 (45 ring shaped illumination,0° observation angle)
RepeatabilityLight splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
SensorHigh sensitivity silicon photodiode
Portable Spectrophotometer : Portable Spectrophotometer LSP-A31
Illumination45/0 (45 ring shaped illumination,0° observation angle)
RepeatabilityLight splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab
SensorHigh sensitivity silicon photodiode
Portable Spectrophotometer : Portable Spectrophotometer LSP-C10
Reflect8º(diffused illumination, 8 degree viewing angle)
Optical GeometrySCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
StandardsISO7724-1, ASTM E1164, DIN5033 Teil7

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A10
Light source150 W Xenon lamp
Excitation wavelength200 nm to 900 nm
Emission wavelength200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A12
Light source150 W Xenon lamp
Excitation wavelength200 nm to 900 nm
Emission wavelength200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A11
Excitation Source150 W Xenon Lamp
Excitation Wavelength200 nm to 900 nm
Excitation Slit1 nm, 2 nm, 5 nm, 10 nm, 20 nm

Xenon Lamp Spectrophotometer

Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A10
Optical systemDouble Beam, Grating 1200 lines/mm
Wavelength Range190 nm to 1100 nm
Spectral Bandwidth2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A11
Optical systemDouble Beam, Grating 1200 lines/mm
Wavelength Range190 nm to 1100 nm
Spectral Bandwidth1 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A13
Optical systemDouble Beam, Grating 1200 lines/mm
Wavelength Range190 nm to 1100 nm
Spectral Bandwidth2 nm