Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | Blue light enhanced sensor array |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03 |
Sensor | Dual light path sensor array |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | Photoelectric diode sensor |
Illumination | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.04 |
Sensor | Photoelectric diode sensor |
Illumination | Observation angles 2°/10° Illumination: d/8 (Diffused lighting, 8° observation angle) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04 |
Sensor | Dual light path sensor array |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Optical Geometry | D/8 (diffused illumination,8° viewing), Specular Component Included (SCI) |
Integrating Sphere Size | Φ 40 mm |
Light Source | LED (Full band balanced LED) |
Optical Geometry | D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded) |
Integrating Sphere Size | Φ 40 mm |
Light Source | LED (Full band balanced LED) |
Reflect | 8º(diffused illumination, 8 degree viewing angle) |
Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
Reflect | 8º(diffused illumination, 8 degree viewing angle) |
Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
Copyright @ labtrononline.com